UL3304 12-22AWG high temperature resistant wire 200℃ cables
This product is a 200℃ silicone high temperature cable certified by UL3304, which is usually used for wiring of electronic ignition or combustion appliance ignition system. UL3304 certification ensures that this cable meets the relevant safety standards and high temperature performance requirements, and is suitable for use in ignition systems. It can work stably in high temperature environments to ensure the reliability and safety of the ignition system. Therefore, UL3304 silicone high temperature cable is an ideal choice for wiring in electronic ignition or combustion appliance ignition systems.
GET A QUOTE
high temperature resistant wire Characterization;
- Good elasticity, softness
- Good adsorption ability
- Good heat resistance
- Good cold resistance
- Good weather resistance
- Good chemical stability
- Good heat dissipation properties
- Good flame retardancy
high temperature resistant wire Electrical Performance:
- Good electrical insulation properties
- With high resistivity
high temperature resistant wire Processing performance:
- Using cold extrusion process
- Or the use of high-temperature vulcanization process
- Good harness processing performance
- Good compatibility in the process of harness processing
- According to UL standard design
high temperature resistant wire Eco-friendly:
- Comply with ROHS/REACH
- Odorless and non-toxic
high temperature resistant wire Appliance:
- Wires for electronic ignition or ignition system of combustion appliances
high temperature resistant wire Reference standard:
- UL758-2010、UL1581-2009
high temperature resistant wire Structure:
- Conductor Construction:Tinned/Bare Conductor
- Insulation Material: Silicone Rubber Insulation
- Braid:Glass fiber braid
Parameter:
Ignition wire, silicone rubber insulated wire with conductor temperature not exceeding 200°C Rated temperature:200℃ Rated voltage:10KVac |
||||||||
---|---|---|---|---|---|---|---|---|
Model | Specification AWG | Conductor Structure(mm)±0.005mm | Conductor Resistance
20℃Ω/Km) |
Conductor Diameter(mm) | Insulation Thickness (mm) |
Finished Outer Diameter(mm) | ||
Average value | Minimum value | Average value | Tolerance | |||||
3304 | 12 | 65/0.254 | 5.64 | 2.36 | 1.02 | 0.92 | 4.80 | ±0.15 |
14 | 41/0.254 | 8.96 | 1.90 | 1.02 | 0.92 | 4.30 | ±0.15 | |
16 | 7/0.49 | 14.60 | 1.50 | 1.02 | 0.92 | 3.90 | ±0.15 | |
18 | 7/0.39 | 23.20 | 1.19 | 1.02 | 0.92 | 3.60 | ±0.15 | |
20 | 7/0.30 | 36.70 | 0.92 | 1.02 | 0.92 | 3.35 | ±0.15 | |
22 | 7/0.254 | 59.40 | 0.76 | 1.02 | 0.92 | 3.20 | ±0.15 | |
22 | 1/0.65 | 59.40 | 0.65 | 1.02 | 0.92 | 3.10 | ±0.15 | |
Braid thickness:0.20mm |