UL3134 12-18AWG high temperature heat resistant wire & cables
The special UL3134 certified cables are professionally designed for the internal wiring needs of electrical appliances in high temperature environments. The cable is able to operate continuously at 150°C, ensuring the stability and safety of electrical appliances under severe working conditions. Its UL3134 certification represents its excellent performance in terms of heat resistance, electrical safety and material quality. Provides a reliable internal connection for your electrical products, ensuring long-term performance maintenance and safe use.
GET A QUOTE
UL3134 12-18AWG high temperature heat resistant wire Characterization;
- Good elasticity, softness
- Good adsorption ability
- Good heat resistance
- Good cold resistance
- Good weather resistance
- Good chemical stability
- Good heat dissipation properties
- Good flame retardancy
UL3134 12-18AWG high temperature heat resistant wire Electrical Performance:
- Good electrical insulation properties
- With high resistivity
UL3134 12-18AWG high temperature heat resistant wire Processing performance:
- Using cold extrusion process
- Or the use of high-temperature vulcanization process
- Good harness processing performance
- Good compatibility in the process of harness processing
- According to UL standard design
UL3134 12-18AWG high temperature heat resistant wire Eco-friendly:
- Comply with ROHS/REACH
- Odorless and non-toxic
UL3134 12-18AWG high temperature heat resistant wire Appliance:
- Internal wiring of electrical appliances
UL3134 12-18AWG high temperature heat resistant wire Reference standard:
- UL758-2010、UL1581-2009
UL3134 12-18AWG high temperature heat resistant wire Structure:
- Conductor structure: tinned/nickel/silvered copper conductor
- Insulation Material: Silicone Rubber Insulation
Parameter:
Silicone rubber insulated wires for internal wiring of electrical appliances with conductor temperature not exceeding 150℃. Rated temperature:150℃ Rated voltage:600V |
||||||||
---|---|---|---|---|---|---|---|---|
Model | Specification AWG | Conductor structure(mm)±0.005mm | Conductor Resistance
20℃Ω/Km) |
Conductor Diameter(mm) | Insulation Thickness (mm) |
Finish Outer Diameter(mm) | ||
Average value | Minimum value | Average value | Tolerance | |||||
3134 | 12 | 19/0.50 | 5.64 | 2.50 | 0.80 | 0.69 | 4.10 | ±0.15 |
12 | 65/0.254 | 5.64 | 2.37 | 0.80 | 0.69 | 3.97 | ±0.15 | |
14 | 41/0.254 | 8.96 | 1.88 | 0.80 | 0.69 | 3.50 | ±0.15 | |
16 | 7/0.49 | 14.60 | 1.50 | 0.80 | 0.69 | 3.10 | ±0.15 | |
18 | 7/0.39 | 23.20 | 1.19 | 0.80 | 0.69 | 2.75 | ±0.15 | |
18 | 41/0.16 | 23.20 | 1.18 | 0.80 | 0.69 | 2.78 | ±0.15 |