JSHFP-30 multi-core shielded watertight cable High voltage1000V
Watertight control cable is mainly used for electrical connection between equipment and is required to work in underwater environment. According to the signal transmission requirements, the signal control line can be composed of multi-strand twisted single-core, multi-core, and multi-pair core wires of different combinations; according to the isolation requirements, the shielding form can be a single-layer shield, a single 2-layer shield, a single-layer total shield, a 2-layer total shield, etc.; according to the use requirements, it can be a longitudinal watertight form or a transverse sealing form.
GET A QUOTE
Longitudinal watertight cable: used for ship piercing connection, high reliability use environment. The cable end face (axial) is required to be able to withstand water pressure, and no water is allowed to seep out within the specified test pressure and time.
Transverse watertight cable: underwater use environment for non-piercing. The cable outer sheath (radial) is required to be able to withstand water pressure, and the cable insulation resistance does not decrease and the cable does not deform within the specified test pressure and time.
Multi-core shielded watertight cable product features
Excellent electrical performance
Good shielding performance
Waterproof and moisture-proof
Excellent seawater corrosion resistance
Product structure
SEF46PJ-56-0.21 type 56-pair shielded watertight cable
Multi-core shielded watertight cable technical parameters
|
Watertight control cables are mainly used for electrical connections between equipment and are required to work in underwater environments. According to signal transmission requirements, signal control cables can be composed of single-core, multi-core, or multi-pair cores of different combinations of stranded strands; according to isolation requirements, the shielding form can be single-layer shielding, double-layer shielding, single-layer overall shielding, double-layer overall shielding, etc.; according to use requirements, it can be longitudinal watertight or transverse sealed.
Longitudinal watertight cable: used for ship docking connection, high reliability use environment. The cable end face (axial) is required to withstand water pressure, and no water is allowed to seep out within the specified test pressure and time.
Transverse watertight cable: underwater use environment for non-dock docking. The cable outer sheath (radial) is required to withstand water pressure, and the cable insulation resistance does not decrease or the cable is not deformed within the specified test pressure and time.
Watertight control cable
Water pressure classification | Longitudinal water pressure resistance | Transverse water pressure resistance | |||
Water pressure level | 4.5MPa | 6.0MPa | 10.0MPa | 10.0MPa | 70.0MPa |
Single core wire | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area 0.12mm2-16mm2. Conductor stranding filled with water-blocking glue. | Multiple strands of tinned copper wire or silver-plated copper wire twisted conductor, conductor cross-sectional area 0.035mm2-16mm2. | |||
Multiple core wires | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area 0.12mm2-16mm2, number of cores: 2 cores-91 cores.
Each shield: tinned wire braiding (when shielding is required); Total shield: tinned wire braiding (when shielding is required). Conductor stranding, braiding, and cabling are all filled with water-blocking glue. |
Multiple strands of tinned copper wire or silver-plated copper wire twisted conductor, conductor cross-sectional area 0.035mm2-16mm2, number of cores: 2 cores-91 cores.
Each shield: tinned wire braiding (when shielding is required); Total shield: tinned wire braiding, or aluminum foil wrapping + tinned wire braiding (when shielding is required). Cable filling sealant. |
|||
Multiple pairs of core wires | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area 0.12mm2-16mm2, number of twisted pairs: 2 pairs-91 pairs.
Each pair: tinned wire braiding (when shielding is required); Total shield: tinned wire braiding (when shielding is required). Conductor stranding, braiding, and cabling are all filled with water-blocking glue. |
Multi-strand tinned copper wire or silver-plated copper wire twisted conductor, conductor cross-sectional area 0.035mm2-16mm2, number of cores: 2 pairs-91 pairs, shielding form:
Each pair: tinned wire braided, or aluminum foil + tinned wire (when shielding is required) braided, or aluminum foil + drainage wire Total shielding: tinned wire braided, or aluminum foil wrapped + tinned wire braided (when shielding is required). Cable filling sealant. |
|||
Working temperature | -50℃-80℃ | ||||
Short-term temperature resistance | Can withstand 130℃, 2h low temperature vulcanization | ||||
Sheath material | Polyurethane, rubber | ||||
Seawater resistance | Applicable | ||||
Watertight test standard | GJB1916-94,GJB774-1989,MIL-DTL-24643 | ||||